Introduction
Stability Chambers are designed as per ICH Guidelines for precise monitoring of temperature and humidity conditions required for the long term, intermediate & accelerated stability studies at chemical, pharmaceutical, agrochemical manufacturing facilities. These chambers are manufactured to comply with GMP requirements.
Salient Features
- CE Certified
- Double-wall construction
- Fulfills storage conditions of 25° C – 60% RH, 40° C – 75% RH, 30° C – 65% RH, 25° C – 40% RH, 30° C – 35% RH
- Designed for testing product shelf – life, Packing, and Electronic test.
- Specially designed to meet ICH, WHO & USFDA requirements.
- Full-size polycarbonate sheet inner door to inspect samples without affecting the control parameters.
- Electrical wiring as per CE Compliances
- Illuminated working area
- User-friendly and tactfully designed chamber door and locking mechanism
- Forced air circulation for uniform temperature and RH Distribution
- Ensures smooth air-flow pattern to improve the Temp & Humidity distribution across the chamber
- U-Shaped tubular heaters as a heating element.
- The unit mounted on castor wheels for easy movement.
- Uniformity module with 4 + 4 RH & Temp Sensors (Optional)
- Password protected door access and monitoring (Optional)
- GSM module for SMS Alert (Optional)
- Serial port for PC interface with 21-CFR Compliant software (Optional software)
- Standby Humidity control system and Standby refrigeration system (Optional)
Insulation
70mm polyurethane insulation (PUF)/ fiberboard to ensure thermal loss
Humidity System
Non-condensing type Steam injection system & reservoir tank with water level arrangement with indicator.
Cooling System
Hermetically sealed compressor, which is CFC free and eco-friendly, utilizes the refrigerant (R-134A gas) to maintain chamber temperature within the specified range.
Technical Specifications
- Temperature Range: 20 °C to 60 °C
- Humidity Accuracy: ± 2% RH
- Temperature Accuracy: ± 0.2 °C
- Humidity Uniformity: ± 3% RH
- Temperature Uniformity: ± 1°C
- Supply: 230V Ac, 50 Hz, Single Phase
- Humidity Range: 40% RH to 95% RH
Trays for samples
- Removable perforated trays
- Can withstand heavy load
- Offer better air circulation
Safety Features
- High-temperature safety cut off
- Low water level boiler cut off
- Electrical overload cut off
- Time delay for compressor switch ON
- Electrical circuit breaker
Salient Features
- 21-CFR Compliance software with PC Communication
- Highly advanced HMI & PLC Control system
- GSM Alert through SIM Card
- Data logger with 4 temperature + 4 Humidity sensors
- Spare RH Sensor for validation purpose
- Spare PT-100 Sensor for validation purpose
- Standby Humidity System
- Standby Refrigeration System
- Biometrics Magnetic Door Access for Secured Door opening with software to maintain a log
- On-Site Validation (mapping) for 24 hours on Empty, Half and Full load condition
Selection Guide
Working chamber sizes (CM) (H x D x W) | Overall dimensions (CM) (H x D x W) | Volume (Liters) | No of trays | Power ratings (KW) | Weight (KG) |
45 x 45 x 45 cm | 119 x 74 x 66 | 92 | 2 | 1.5 | 115 |
70 x 50 x 50 cm | 145 x 76 x 71 | 175 | 3 | 1.5 | 135 |
60 x 60 x 60 cm | 135 x 84 x 81 | 216 | 3 | 2.0 | 150 |
90 x 60 x 60 cm | 165 x 84 x 81 | 324 | 3 | 2.0 | 157 |
125 x 60 x 60 cm | 201 x 84 x 81 | 450 | 4 | 2.5 | 175 |
125 x 70 x 70 cm | 201 x 94 x 91 | 612 | 4 | 2.5 | 198 |
125 x 80 x 80 cm | 201 x 104 x 102 | 800 | 5 | 3.0 | 220 |
125 x 90 x 90 cm | 201 x 114 x 112 | 1000 | 5 | 3.0 | 245 |